Protective gloves for appropriate occupational X-ray environments; confirm model protection level, size and applicable handling requirements before procurement.
Select a product to view complete specifications, variants and quotation options.
Protective gloves are one element of an occupational radiation-safety programme. Confirm that the selected model is appropriate for the task and review the exact published lead equivalency, size, fit and handling requirements before procurement.
Protective gloves for appropriate occupational X-ray environments; confirm model protection level, size and applicable handling requirements before procurement.
IndoSurgicals Private Limited is a lead gloves manufacturer, supplier, and exporter in India, offering specialised radiation protection gloves for healthcare professionals working around medical X-ray equipment. Our Lead Gloves for X-Ray Protection are designed to provide an attenuating barrier around the hands and fingers during appropriate radiological and image-guided procedures where occupational exposure to scattered X-ray radiation may occur.
The IndoSurgicals Lead Gloves are manufactured with a lead-rubber radiation shielding core and are currently available in 0.50 mmPb lead equivalency. This defined protection level makes the product suitable for institutional buyers looking for an X-ray protective glove with a clearly stated shielding specification rather than a general-purpose glove with an unspecified radiation attenuation level.
Hands can be positioned relatively close to the patient and X-ray equipment during certain fluoroscopic, interventional, orthopaedic, urological, dental, and C-arm-assisted procedures. A properly used X-ray protection glove can provide supplementary shielding against scattered radiation reaching the hands and fingers. Protective gloves should form part of a wider radiation-safety programme and should not be considered a substitute for appropriate positioning, working distance, protective barriers, equipment optimisation, and established radiation-protection procedures.
Lead gloves should also not be used as a reason to intentionally place the hands within the primary X-ray beam. Whenever clinically possible, healthcare professionals should keep their hands outside the direct beam and use shielding, positioning techniques, and other exposure-reduction measures specified by their institution. The glove provides an additional attenuating layer but does not eliminate radiation exposure.
The 0.50 mmPb lead gloves are intended for healthcare environments such as radiology departments, cath labs, C-arm procedure rooms, diagnostic imaging centres, hospitals, dental facilities, urology departments, medical colleges, and other locations where trained personnel may work near X-ray equipment. Potential users include radiologists, surgeons, radiographers, X-ray technicians, dentists, urologists, interventional specialists, and other appropriately trained healthcare professionals.
Unlike ordinary examination gloves, a radiation protection glove is selected primarily for its shielding function. The current IndoSurgicals model uses lead rubber as its protective core and has a specified lead equivalency of 0.50 mmPb. Buyers requiring additional properties such as sterility, infection-barrier certification, a particular glove size, chemical resistance, or suitability for a specific surgical application should confirm those requirements separately before procurement.
Correct fit and condition are important when using reusable radiation protection gloves. The gloves should be inspected regularly for visible damage, deterioration, cracking, or other signs that could affect their protective condition. Storage should avoid unnecessary compression, sharp folding, excessive heat, or mechanical stress, and cleaning should follow a method compatible with the glove material and the healthcare facility’s infection-control procedures.
When comparing lead gloves for radiology, institutional buyers should consider lead equivalency, shielding material, glove construction, fit, flexibility, intended procedure, expected wearing duration, cleaning requirements, and available technical documentation. Lead equivalency describes radiation attenuation relative to a corresponding thickness of lead and should not be confused with the physical thickness of the complete glove.
As a radiation protection apparel manufacturer in India, IndoSurgicals supplies X-ray protective gloves to hospitals, diagnostic centres, cath labs, medical colleges, healthcare institutions, distributors, dealers, government and private organisations, project buyers, and international customers. We support bulk lead glove requirements, institutional procurement, distributor enquiries, and export orders with product-selection and quotation assistance. Review the Lead Gloves for X-Ray Protection above and contact IndoSurgicals with your required quantity for institutional or export pricing.
Radiation-protection gloves should be selected as part of the facility's overall controls. Do not use the presence of a glove as a reason to place hands in the primary beam or ignore the applicable radiation-safety procedure.
Before purchase, confirm the exact model, quantity, destination, required variant or protection level, accessories, current availability and any documentation that must accompany the quotation or tender submission.
Please send your Lead Gloves requirement with the required quantity and delivery destination to info@indosurgicals.com for current availability and quotation details.
Product images and specifications are provided for general reference. Product design, colour, packaging and specifications may be updated without prior notice. Please confirm current specifications, certification scope and regulatory applicability before ordering.