Product Details

Radiation Protection - Hands and Fingers

Lead Gloves for X-Ray Protection - 0.50 mm Pb

Reusable radiation-protection gloves with a lead-rubber shielding core and a published 0.50 mm Pb lead equivalency for the covered hands and fingers during applicable medical X-ray procedures.

Product Highlights

0.50 mm Pb

Fixed published protection level for this model.

Lead-Rubber Core

The current specification identifies lead rubber as the shielding core.

Hand and Finger Coverage

Designed to provide additional shielding over the covered portions of the hands and fingers.

Reusable Radiation PPE

Inspect, clean and store as reusable radiation-protection equipment.

Intended Use

Supplementary Protection Against Scattered Diagnostic X-Rays

Lead Gloves can form part of an occupational radiation-protection programme for applicable fluoroscopy, C-arm, interventional, cath-lab, surgical-imaging and other medical X-ray procedures where the hands may be exposed to scattered radiation.

They do not make deliberate hand placement in the primary X-ray beam safe. Keep hands outside the direct beam whenever possible and use appropriate positioning, distance, shielding, collimation and procedural controls.

Published Specification

Fixed Lead-Rubber Configuration

Core material

Lead rubber.

Lead equivalency

0.50 mm Pb only for this model.

Protective region

Covered portions of the hands and fingers.

Size and fit

Confirm the required glove size and fit before procurement; a size range is not published in the current product record.

Configuration note: this model is not listed with StPb®, NoPb®-LT, NoPb®-SL or NoPb®-BL selectable cores. Do not infer material variants from other IndoSurgicals radiation-protection products.
Care and Inspection

Protect the Shielding Core and Glove Condition

Inspect Before Use

Check for visible damage, cracking, deterioration or other defects that may affect protective condition.

Avoid Mechanical Stress

Store without sharp folding, crushing, excessive heat or unnecessary compression.

Clean Appropriately

Use a cleaning and disinfection method compatible with the glove material and the facility's approved procedure.

Procurement Support

Confirm the Exact Clinical and Institutional Requirement

For quotation support, provide the required quantity, glove-size requirement, intended use context, delivery destination and any tender, inspection or documentation requirement that must be confirmed before supply.

Hospital - Institutional - Dealer - Distributor - Export

Request a Current Lead Gloves Quotation

Confirm the 0.50 mm Pb lead-rubber configuration, required size and quantity before ordering.