Medical Equipment Manufacturer
Certified Quality System ISO 9001 & ISO 13485
Quotation list Enquiry Cart 0
IndoSurgicals Product

Full Protection - Partial Over Lap (Wrap Around Lead Apron)

Manufacturer Direct Bulk & Export Enquiries Product Selection Support
Request pricing

Get a Free Quotation

No obligation
SKU 91653 Brand IS IndoSurgicals®
Select exact configuration

Choose Product Options

Ready
Selected configuration Material: StPb® (Lite Lead) / Lead Equivalency: 0.50mm / Size: Medium SKU: 91653

Add this product to your enquiry cart and submit all required products together for one consolidated quotation.

Need assistance? Mon–Sat, 11:00 AM–5:00 PM
Call 075054 56099
Complete information

Product Details

Full-Protection Partial-Overlap Radiation Apron

IS IndoSurgicals® Full Protection – Partial Overlap Wrap Around Lead Apron

A wrap-around radiation-protection apron designed to provide front and rear torso protection while reducing unnecessary garment weight through a partial-overlap frontal construction. The apron is available with 0.35 mmPb or 0.50 mmPb nominal front protection and 0.25 mmPb rear protection, with the correctly overlapped frontal region providing double the selected nominal lead equivalence.

Front: 0.35 / 0.50 mmPb Back: 0.25 mmPb Partial-Overlap Front Lead & Lead-Free Options

Wrap-Around Protection with a Weight-Conscious Partial-Overlap Design

The apron is designed for healthcare professionals who require protection from both frontal and rear scatter radiation during diagnostic, fluoroscopic and image-guided procedures. Its partial-overlap construction increases protection only through the intended overlapping frontal region, helping avoid the additional weight of a full-overlap design across the entire frontal area.

Front and Rear Coverage

The apron wraps around the torso to provide nominal front protection of 0.35 mmPb or 0.50 mmPb, together with consistent 0.25 mmPb protection at the back.

Partial-Overlap Construction

The frontal panels overlap through the intended central region rather than across the entire front, providing enhanced shielding where the panels overlap while reducing overall garment weight.

Overlap note: Only the correctly overlapped frontal region receives the combined protection of both layers. Areas outside that overlap retain the selected nominal front protection level.

Selectable Front Protection with 0.25 mmPb Rear Coverage

The apron can be configured with either 0.35 mmPb or 0.50 mmPb nominal front protection. The rear panel remains at 0.25 mmPb in both configurations.

0.35 mmPb Front

Nominal frontal protection option where the approved radiation-safety protocol permits 0.35 mmPb.

0.50 mmPb Front

Higher nominal frontal protection option for procedures or departments requiring 0.50 mmPb.

0.25 mmPb Back

Consistent rear protection helps provide comprehensive wrap-around coverage of the wearer.

Overlapped region: When the frontal panels are correctly overlapped, the two layers provide approximately 0.70 mmPb in the 0.35 mmPb configuration and approximately 1.00 mmPb in the 0.50 mmPb configuration.

Designed for Protection, Stability and Practical Clinical Wear

Tested Core Materials

Available with StPb®, NoPb®-LT, NoPb®-SL and NoPb®-BL radiation-protection core options.

Partial-Overlap Front

Overlapping frontal panels enhance protection through the intended overlap region while limiting excess weight.

Wrap-Around Coverage

The apron provides protection to both the front and back of the torso for comprehensive wearable shielding.

Padded Shoulders

Shoulder padding helps reduce concentrated pressure during prolonged use.

Waist Support

Waist straps and buckle fastening help transfer part of the garment load away from the shoulders.

Hook-and-Loop Closure

The front closure supports straightforward donning, removal and adjustment.

Dosimeter Pocket

A front pocket provides a convenient location for a personal dosimeter badge where required.

PU-Coated Outer Fabric

The outer fabric is designed for routine clinical handling and cleaning according to current care instructions.

Weight-Conscious Design

The partial-overlap construction is intended to balance protection with lower garment weight than a comparable full-overlap configuration.

Four Core Choices for Shielding, Weight and Procurement Requirements

Four core-material options are listed. Approximate values below are core area densities per square metre, not finished apron weights.

StPb® — Conventional Lead-Vinyl

Approximate core area density: 4.62 kg/m² at 0.35 mmPb and 6.60 kg/m² at 0.50 mmPb.

Learn more about StPb® →

NoPb®-LT — Lead-Free Lightweight

Approximate core area density: 4.50 kg/m² at 0.35 mmPb and 6.00 kg/m² at 0.50 mmPb.

Learn more about NoPb®-LT →

NoPb®-SL — Lead-Free Super Lightweight

Approximate core area density: 3.90 kg/m² at 0.35 mmPb and 5.20 kg/m² at 0.50 mmPb.

Learn more about NoPb®-SL →

NoPb®-BL — Lead-Free Broad-Beam Tested

Approximate core area density: 4.29 kg/m² at 0.35 mmPb and 6.00 kg/m² at 0.50 mmPb.

Learn more about NoPb®-BL →

Weight note: Finished apron weight also depends on garment size, fabric, stitching, binding, straps, buckle, pocket and other components.

For Healthcare Environments Requiring Front and Rear Radiation Protection

The apron is intended for professional radiation-protection use in diagnostic and image-guided medical environments. Suitability should be determined according to the actual procedure, staff movement and institutional radiation-safety protocol.

Cardiac Cath Labs

For fluoroscopy-guided cardiac procedures where staff may remain near the radiation field for extended periods.

EP Laboratories

Suitable for prolonged electrophysiology procedures involving fluoroscopic imaging.

Radiology Departments

For radiologists, technicians and supporting personnel working around diagnostic X-ray equipment.

C-Arm Procedures

For surgical teams working around mobile fluoroscopy equipment during image-guided procedures.

Urology Procedures

For clinicians working with fluoroscopic imaging in urology and related procedure rooms.

Dental & Diagnostic Clinics

For professionals requiring wrap-around radiation protection during applicable diagnostic imaging procedures.

Technical Specifications

Product TypeFull Protection Partial-Overlap Wrap Around Lead Apron
Protection DesignWrap-around apron with partial frontal overlap and rear coverage
Core-Material OptionsStPb®, NoPb®-LT, NoPb®-SL and NoPb®-BL
Front Protection0.35 mmPb or 0.50 mmPb lead equivalent
Overlapped RegionApproximately 0.70 mmPb in the 0.35 mmPb configuration and 1.00 mmPb in the 0.50 mmPb configuration when correctly overlapped
Back Protection0.25 mmPb lead equivalent
Closure SystemHook-and-loop closure with waist straps and buckle fastening
Shoulder SupportPadded shoulders for improved wearing comfort
Dosimeter PocketFront pocket for personal dosimeter badge placement
Outer FabricPolyurethane-coated outer fabric
Available SizesXS, S, M, L, XL and XXL
Colour OptionsAvailable in multiple colours; customization subject to order requirements and production feasibility
Recommended UsersRadiologists, technicians and other professionals requiring front and rear wearable radiation protection
ManufacturerIndoSurgicals Private Limited, New Delhi, India

What to Confirm Before Ordering

Protection Level

Select 0.35 mmPb or 0.50 mmPb frontal protection according to the approved radiation-safety requirement.

Core Material

Choose conventional lead-vinyl or a lead-free core according to shielding, weight and documentation requirements.

Correct Overlap

Enhanced frontal shielding applies only where the designated front panels are correctly overlapped.

Apron Fit

Confirm the correct garment size so front, rear and intended overlap coverage are maintained during normal working posture.

Protect the Radiation-Shielding Core from Avoidable Damage

Recommended Handling

Store flat or on a suitable radiation-apron hanger. Avoid folding, sharp creasing or placing heavy objects on the protective core. Clean the outer surface using a compatible mild cleaning method and allow the apron to dry before storage.

Routine Inspection

Inspect the fabric, seams, hook-and-loop closure, straps, buckle and shoulder support regularly. Follow the facility schedule for integrity inspection and remove the apron from use if shielding-core damage is suspected.

Partial-Overlap Wrap Around Lead Apron FAQs

What is a partial-overlap wrap-around lead apron?
It is a full-protection apron that wraps around the torso to protect the front and back. The front panels overlap only through the intended central region rather than across the entire front.
How is partial overlap different from full overlap?
In a partial-overlap apron, only part of the frontal area carries two layers when the apron is correctly closed. A full-overlap model extends the doubled frontal layer across a broader frontal region, which generally increases garment weight.
Which front protection levels are available?
The apron is available with 0.35 mmPb or 0.50 mmPb nominal front protection. Rear protection remains 0.25 mmPb.
Does the overlapped region provide higher lead equivalence?
Yes. Where two frontal layers correctly overlap, the combined region provides approximately 0.70 mmPb in the 0.35 mmPb configuration and approximately 1.00 mmPb in the 0.50 mmPb configuration.
Why choose a partial-overlap model?
It is intended to provide comprehensive front and rear protection while reducing some of the extra weight associated with a broader full-overlap frontal construction.
Are lead-free options available?
Yes. The current product information lists NoPb®-LT, NoPb®-SL and NoPb®-BL lead-free options in addition to StPb® conventional lead-vinyl.
Safety note: Radiation-protection garments reduce exposure; they do not eliminate radiation risk. Use them together with appropriate distance, positioning, shielding, dosimetry, equipment settings and the healthcare facility’s approved radiation-safety procedures.