CMS6000 Multi-Parameter Patient Monitor
A portable multi-parameter patient monitor designed for continuous monitoring of adult, pediatric and neonatal patients. The CMS6000 combines ECG, respiration, SpO₂, pulse rate, non-invasive blood pressure and dual-channel temperature monitoring on an 8-inch TFT colour LCD, with alarm review, trend storage and rechargeable battery operation.
Continuous Multi-Parameter Monitoring for Clinical Care
The CMS6000 is intended for continuous observation of vital signs in hospitals, surgery centres, clinics and other supervised healthcare environments. It supports adult, pediatric and neonatal patient categories and provides audible/visual alarms, trend review and event storage.
ECG Monitoring
Heart rate, ECG waveform, arrhythmia analysis and ST-segment monitoring using 3-lead or 5-lead configurations.
Respiration
Respiration rate and waveform monitoring using R-F (RA-LL) impedance measurement.
SpO₂ & Pulse Rate
Oxygen saturation, plethysmogram waveform, pulse rate and bar-graph display.
Non-Invasive Blood Pressure
Oscillometric NIBP measurement with Manual, AUTO and STAT operating modes.
Dual-Channel Temperature
Two temperature channels support T1, T2 and temperature-difference display.
Optional Expansion
EtCO₂ and dual-channel invasive blood pressure monitoring are available as optional functions.
Designed for Practical Bedside Monitoring
Fanless Design
Supports quiet, energy-efficient operation while reducing unnecessary airflow around the device.
Flexible Display Modes
Includes OxyCRG, trend chart, large-character interface and view-bed display options.
Customizable Screen
Waveform, parameter colour and on-screen location can be configured according to user preference.
Multi-Waveform Display
Displays up to 8 channels of waveform and up to 7-lead ECG waveform information on one screen.
Digital SpO₂ Technology
Designed with anti-motion and anti-ambient-light interference capability, including weak-perfusion measurement support.
HRV Analysis
Includes heart-rate-variability analysis as part of the ECG monitoring functions.
Alarm Event Review
Stores review data for 71 all-parameter alarm events and 60 arrhythmia alarm events.
Drug Calculation
Includes drug-concentration calculation and titration-table functions.
Battery Operation
Supports AC/DC operation using a built-in rechargeable lithium battery.
Portable 8-Inch Monitor with Central-Monitoring Connectivity
The supplied specification describes an 8-inch TFT colour LCD, multi-language user interface and connectivity to a central monitoring system through 3G, Wi-Fi or wired modes. A USB interface is provided for data storage and software updates.
Multi-Language Interface
Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish and Czech are listed in the supplied specification.
Central Monitoring
Supports central-monitor connectivity through 3G, Wi-Fi or wired modes, with USB available for storage and software updates.
Core Monitoring Functions
| ECG | Heart rate, ECG waveform, arrhythmia analysis and ST-segment analysis |
|---|---|
| RESP | Respiration rate and respiration waveform |
| SpO₂ | Oxygen saturation, plethysmogram waveform, pulse rate and bar graph |
| NIBP | Systolic pressure, diastolic pressure and mean pressure |
| TEMP | Dual-channel temperature: T1, T2 and TD |
ECG Monitoring Specifications
| Lead Mode | 3-lead or 5-lead |
|---|---|
| Lead Selection | I, II, III, aVR, aVL, aVF, V |
| Waveform | 5-lead: 2-channel; 3-lead: 1-channel |
| Gain | 2.5 / 5.0 / 10 / 20 / 40 mm/mV |
| Scan Speed | 12.5 / 25 / 50 mm/s |
| HR Measurement Range | 15-350 bpm |
| HR Accuracy | ±1% or ±1 bpm, whichever is greater |
| Alarm Accuracy | ±2 bpm |
| Resolution | 1 bpm |
| ST Measurement Range | −2.0 mV to +2.0 mV |
| ST Accuracy | Within −0.8 mV to +0.8 mV: ±0.04 mV or ±10%, whichever is greater |
Respiration Monitoring Specifications
| Method | R-F (RA-LL) impedance |
|---|---|
| Respiration Rate Range | 0-150 rpm |
| Resolution | 1 rpm |
| Accuracy | ±2 rpm |
| Alarm Accuracy | ±3 rpm |
| Apnea Alarm | 10-40 seconds |
| Scan Speed | 6.25 / 12.5 / 25 mm/s |
Non-Invasive Blood Pressure Specifications
| Method | Oscillometry |
|---|---|
| Modes | Manual, AUTO, STAT |
| Measurement Interval | 1 / 2 / 3 / 4 / 5 / 10 / 15 / 30 / 60 / 90 / 120 / 240 / 480 / 960 minutes |
| STAT Mode | 5 minutes |
| Measurement Range | 10-270 mmHg |
| Resolution | 1 mmHg |
| Cuff Pressure Accuracy | ±3 mmHg |
| Measurement Accuracy | Maximum mean deviation ±5 mmHg; maximum standard deviation 8 mmHg |
| Over-Pressure Protection | Adult 297±3 mmHg; Pediatric 240±3 mmHg; Neonatal 147±3 mmHg |
| Stored NIBP Data | Up to 4,800 data points |
Oxygen Saturation and Temperature Specifications
SpO₂ / Pulse Rate
| SpO₂ Range | 0-100% |
|---|---|
| Resolution | 1% |
| Accuracy | 70-100%: ±2%; 0-69%: unspecified |
| PR Range | 30-250 bpm |
| PR Accuracy | ±2 bpm or ±2%, whichever is greater |
Temperature
| Channels | Dual-channel |
|---|---|
| Range | 0-50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C |
EtCO₂ and Invasive Blood Pressure Options
EtCO₂ and IBP are optional configurations and should not be assumed to be included in the standard monitor unless specifically ordered.
EtCO₂ - Optional
| Method | Sidestream or mainstream |
|---|---|
| CO₂ Range | 0-150 mmHg |
| CO₂ Resolution | 0.1 mmHg from 0-69 mmHg; 0.25 mmHg from 70-150 mmHg |
| CO₂ Accuracy | 0-40: ±2 mmHg; 41-70: ±5%; 71-100: ±8%; 101-150: ±10% |
| AwRR Range | 2-150 rpm |
| AwRR Accuracy | ±1 rpm |
| Apnea Alarm | Yes |
IBP - Optional
| Channels | Dual-channel |
|---|---|
| Labels | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
| Range | −10 to 300 mmHg |
| Resolution | 1 mmHg |
| Accuracy | ±2% or 1 mmHg, whichever is greater |
Clinical Review and Workflow Functions
Trend Storage
Supports storage and output of trend data for retrospective review.
Alarm Event Review
Stores up to 71 alarm events for all parameters.
Arrhythmia Review
Stores up to 60 arrhythmia alarm events.
Drug Calculation
Includes drug-concentration calculation and titration-table functions.
One-Key Printing
Supports one-key printing of trend-table data when configured with a compatible printer.
Audible & Visual Alarms
Provides audible and visual alarm notification for monitored parameters.
Power Supply and Electrical Classification
| Power Requirement | 100-240 V~, 50/60 Hz |
|---|---|
| Operating Modes | AC/DC operation |
| Battery | Built-in rechargeable lithium battery |
| Safety Classification | Class I, type CF defibrillation-proof applied part |
| Additional Protection | Anti-high-frequency surgical-unit interference and defibrillation-proof design with special leads |
Standard and Optional Accessories
Standard Accessories
- Adult fingertip SpO₂ probe (5-pin)
- Adult NIBP cuff
- NIBP extension tube
- ECG lead cable
- ECG electrode
- Temperature probe
- Power adapter
- Power cord
- User manual
Optional Accessories / Functions
- EtCO₂
- IBP
- Printer
- Trolley
Compact Portable Monitor
| Display | 8-inch TFT colour LCD |
|---|---|
| Dimensions | 235 mm (L) × 141 mm (W) × 222 mm (H) |
| Weight | Approximately 2.5 kg |
| Patient Categories | Adult, pediatric and neonatal |
| Conformity Documentation | Request current documentation for the supplied revision when required for procurement. |