Medical Equipment Manufacturer
Certified Quality System ISO 9001 & ISO 13485
Quotation list Enquiry Cart 0
IndoSurgicals Product

Thyroid Collar Standard

Manufacturer Direct Bulk & Export Enquiries Product Selection Support
Request pricing

Get a Free Quotation

No obligation
SKU 91712 Brand IS IndoSurgicals®
Select exact configuration

Choose Product Options

Ready
Selected configuration Material: StPb® (Lite Lead) / Lead Equivalency: 0.50mm / Size: Adult SKU: 91712

Add this product to your enquiry cart and submit all required products together for one consolidated quotation.

Need assistance? Mon–Sat · 10:00 AM–5:00 PM IST
Call +91 9350093400
Complete information

Product Details

Radiation Protection · Thyroid Shield

Thyroid Collar Standard for X-Ray & Fluoroscopy Radiation Protection

The IndoSurgicals Thyroid Collar Standard is a wearable radiation-protection shield designed to cover the thyroid and neck region during applicable diagnostic X-ray, fluoroscopy and image-guided procedures. It is available with 0.35 mm Pb or 0.50 mm Pb lead equivalency, adult and child size options, and a choice of conventional lead-vinyl or lead-free radiation-protection core materials.

0.35 / 0.50 mm Pb Adult & Child Sizes Lead & Lead-Free Options Hook-and-Loop Closure
Product Overview

Standard X-Ray Thyroid Collar for Healthcare Professionals

The thyroid gland is located in the neck and can receive scattered radiation during procedures involving ionising X-rays. A properly selected radiation protection thyroid collar provides an additional shielding layer over this region as part of a healthcare facility's overall radiation-safety programme.

IndoSurgicals manufactures the Standard Thyroid Collar for hospitals, radiology departments, diagnostic centres, cath labs, operation theatres using C-arm imaging, urology departments and dental X-ray facilities. It may be used by doctors, surgeons, radiologists, radiographers, technicians, nurses and other healthcare personnel when thyroid shielding is indicated by procedure and facility protocol.

Select the required protection level, core material and size according to the procedure, fit, wearing duration and the healthcare facility's radiation-protection assessment.

Thyroid Region Coverage

Designed to provide a protective shielding layer around the neck and thyroid region during applicable radiological procedures.

Two Protection Levels

Available in 0.35 mm Pb and 0.50 mm Pb lead-equivalent configurations.

Adult & Child Sizes

Separate adult and child size options support more appropriate coverage and fit for different users.

Adjustable Closure

Hook-and-loop fastening supports convenient wearing, removal and adjustment around the neck.

Bound Edges

Ends and corners are bound with skin-friendly fabric to improve comfort around exposed edges.

PU-Coated Outer Fabric

The current product specification lists a PU-coated outer fabric with antimicrobial and anti-odour properties.

Core Material Options

Choose Conventional Lead Vinyl or Lead-Free Radiation Protection

The Thyroid Collar Standard is offered with multiple IndoSurgicals radiation-protection core-material options. Material selection can influence weight, flexibility, lead content and the type of shielding-test documentation required by the buyer.

StPb® — Lead Vinyl

Conventional lead-vinyl shielding core for buyers who prefer traditional, economical lead-based radiation protection.

0.35 mm Pb reference apron-core area density: approx. 4.62 kg/m² 0.50 mm Pb reference apron-core area density: approx. 6.60 kg/m²
Learn more about StPb® →

NoPb®-LT — Lead-Free Lightweight

Lead-free lightweight shielding material designed to balance practical weight, flexibility and diagnostic X-ray protection.

0.35 mm Pb reference apron-core area density: approx. 4.50 kg/m² 0.50 mm Pb reference apron-core area density: approx. 6.00 kg/m²
Learn more about NoPb®-LT →

NoPb®-SL — Lead-Free Super Lightweight

Super-lightweight lead-free shielding core intended where reducing garment core weight is an important consideration.

0.35 mm Pb reference apron-core area density: approx. 3.90 kg/m² 0.50 mm Pb reference apron-core area density: approx. 5.20 kg/m²
Learn more about NoPb®-SL →

NoPb®-BL — Lead-Free Broad-Beam Tested

Premium lead-free shielding material intended for buyers who specifically require broad-beam test data and associated technical documentation.

0.35 mm Pb reference apron-core area density: approx. 4.29 kg/m² 0.50 mm Pb reference apron-core area density: approx. 6.00 kg/m²
Learn more about NoPb®-BL →
Material-weight note: the area-density figures above are reference values for the stated IndoSurgicals apron-core constructions and are useful for comparing core materials. They are not the finished weight of the thyroid collar. Finished collar weight depends on size, selected material, outer fabric, binding and closure components.
Lead Equivalency

0.35 mm Pb and 0.50 mm Pb Thyroid Protection Options

The required lead-equivalency level should be selected according to the imaging procedure, expected scatter conditions, facility radiation-safety programme and applicable regulatory or institutional requirements.

0.35 mm Pb

Available for applications where the healthcare facility specifies 0.35 mm Pb thyroid-region protection. Material and size should be selected for the intended procedure and user.

0.50 mm Pb

Available where 0.50 mm Pb lead-equivalent thyroid shielding is specified by facility protocol, procurement requirement or procedure.

Selection note: higher stated lead equivalency generally increases shielding material, although finished weight also depends on the selected core material and collar size. The protection level should not be selected on weight alone.
Size, Fit & Closure

Adult and Child Size Options

Correct positioning is important because a thyroid shield should cover the intended neck and thyroid region without creating unnecessary discomfort or interfering with the clinical procedure.

Adult Size

Adult-size configuration for healthcare professionals and other adult users requiring thyroid-region radiation protection.

Child Size

Smaller-size configuration for users requiring a reduced collar fit. The size label describes fit only and does not imply routine patient thyroid shielding.

Hook-and-Loop Closure

Adjustable hook-and-loop fastening provides a practical method for fitting, securing and removing the collar.

Comfortable Edge Binding

Bound ends and corners help isolate the shielding material from exposed edges and support comfortable contact around the neck.

Applications

Typical Clinical Environments for a Thyroid Radiation Shield

The Standard Thyroid Collar is intended for applicable occupational environments where trained personnel require additional thyroid-region protection from scattered X-ray radiation.

Radiology Departments

For applicable diagnostic imaging procedures requiring wearable thyroid-region radiation protection.

Cath Labs

Suitable for specified interventional workflows involving fluoroscopic imaging and occupational scatter exposure.

C-Arm Procedures

For operation theatres and procedure rooms using mobile C-arm imaging where thyroid shielding is required.

Urology Procedures

For applicable fluoroscopy-assisted urology procedures subject to facility radiation-safety requirements.

Dental Imaging Environments

May be selected for occupational use by dental personnel around X-ray equipment where thyroid-region protection is required. Routine patient thyroid shielding should not be assumed and should follow current professional guidance, imaging protocol, facility policy and local requirements.

Hospitals & Diagnostic Centres

Suitable for departments requiring reusable X-ray radiation-protection apparel for trained staff.

Patient-use guidance: Adult and Child are size/fit configurations. Routine patient thyroid shielding should not be assumed. Any patient application should follow current professional guidance, the imaging protocol, facility policy and applicable local requirements.
Technical Specifications

Thyroid Collar Standard Specifications

Product Type Standard thyroid collar / thyroid radiation shield
Primary Protective Area Thyroid and neck region
Lead Equivalency Available in 0.35 mm Pb and 0.50 mm Pb
Core Material Options StPb® lead vinyl, NoPb®-LT lead-free lightweight, NoPb®-SL lead-free super lightweight and NoPb®-BL lead-free broad-beam tested
Size Options Adult and child
Closure Adjustable hook-and-loop fastening
Edge Finish Ends and corners bound with skin-friendly fabric
Outer Fabric PU-coated outer fabric; current specification lists antimicrobial and anti-odour properties
Core Material Testing IndoSurgicals documentation states that the listed radiation-protection core materials are tested for shielding performance at BARC. Confirm the applicable test report and documentation scope for the exact material and protection level being ordered.
Typical Use Applicable diagnostic X-ray, fluoroscopy, C-arm, cath-lab, urology and dental imaging environments
Care, Storage & Inspection

Protect the Shielding Core from Unnecessary Mechanical Stress

Avoid Sharp Folding

Store the thyroid collar without tight folds, sharp creases or prolonged crushing that could stress the internal shielding material.

Inspect Regularly

Periodically inspect the outer cover, binding, fastening system and overall condition according to the healthcare facility's quality-assurance programme.

Follow Approved Cleaning Guidance

Use cleaning and disinfection methods compatible with the outer fabric and shielding core. Avoid unapproved chemicals or processes that may damage the garment.

Procurement Support

Product Selection and Quotation Support

IndoSurgicals Private Limited manufactures and supplies radiation-protection apparel and accessories for hospitals, diagnostic centres, healthcare institutions, dealers, distributors and international medical-equipment buyers.

The Standard Thyroid Collar is available for domestic, institutional, dealer, distributor and export enquiries. For domestic, institutional, dealer, distributor or export enquiries, share the required configuration, core material, size, quantity, destination and documentation requirements.

Institutional · Dealer · Export Enquiries

Need Thyroid Collars for Your Hospital or Distribution Requirement?

Contact IndoSurgicals with the required size, lead equivalency, core material and quantity for current specifications and quotation.

Frequently Asked Questions

Thyroid Collar Standard FAQs

What is a thyroid collar used for?
A thyroid collar is a wearable radiation-protection shield designed to cover the thyroid and neck region during applicable medical imaging procedures involving ionising X-rays.
Which lead-equivalency options are available?
The Standard Thyroid Collar is available in 0.35 mm Pb and 0.50 mm Pb lead-equivalent protection options.
Is the thyroid collar available in lead-free material?
Yes. Lead-free core options include NoPb®-LT, NoPb®-SL and NoPb®-BL. StPb® conventional lead vinyl is also available.
What is the difference between StPb® and NoPb® materials?
StPb® is a conventional lead-vinyl shielding material. NoPb®-LT, NoPb®-SL and NoPb®-BL are lead-free core materials developed for different balances of weight, performance and technical-documentation requirements.
Are adult and child sizes available?
Yes. The current product specification lists both adult and child size options.
How is the thyroid collar secured?
It uses an adjustable hook-and-loop closure for convenient fitting, securing and removal.
Are the radiation-protection core materials BARC tested?
IndoSurgicals documentation states that the listed core materials are tested for radiation-shielding performance at BARC. Institutional and regulated buyers should confirm the applicable test report and documentation scope for the exact material, thickness and supplied configuration.
Where can the Standard Thyroid Collar be used?
Typical environments include hospitals, radiology departments, diagnostic centres, cath labs, C-arm procedure rooms, urology departments and dental imaging facilities when thyroid shielding is appropriate.
Does a thyroid collar replace other radiation-safety measures?
No. A thyroid collar is one component of radiation protection. Time, distance, structural shielding, procedure optimisation, personal protective equipment and facility radiation-safety protocols remain important.
Radiation-safety note: this product is intended to reduce exposure to scattered ionising radiation at the covered thyroid/neck region. It does not eliminate radiation exposure and does not replace established radiation-safety principles, appropriate shielding, procedure optimisation, dosimetry or facility-specific protocols. The required lead equivalency, material and size should be selected according to the intended procedure and applicable regulatory or institutional guidance.