IS IndoSurgicals® Full Protection – Full Overlap Wrap Around Lead Vest & Skirt
A two-piece wrap-around radiation-protection garment designed to protect the front and back of the upper and lower torso while distributing garment weight between the shoulders, waist and hips. Full-overlap front panels provide enhanced shielding through the central frontal region when correctly positioned, while the separate vest-and-skirt construction supports improved comfort during longer procedures.
Full Wrap-Around Protection with Two-Piece Weight Distribution
The garment combines an upper protective vest with a lower wrap-around skirt. Both sections provide front and rear coverage, while the two-piece format prevents the entire garment load from being carried only by the shoulders. This can improve comfort for clinicians who wear radiation-protection apparel for extended periods.
Upper-Torso Protection
The wrap-around vest protects the front and back of the upper torso and uses full-overlap frontal panels through the central protected region when correctly positioned.
Lower-Torso Protection
The separate wrap-around skirt extends protection over the lower torso while transferring part of the garment load to the waist and hips.
Selectable Front Protection with Consistent Rear Coverage
The garment is available with either 0.35 mmPb or 0.50 mmPb nominal frontal protection while maintaining 0.25 mmPb protection at the back.
0.35 mmPb Front
Nominal frontal protection option for applications where the approved radiation-safety protocol permits 0.35 mmPb.
0.50 mmPb Front
Higher nominal frontal protection option for procedures or departments requiring 0.50 mmPb.
0.25 mmPb Back
Rear panels provide 0.25 mmPb protection to support wrap-around coverage of the torso.
Designed for Protection, Stability and Extended Clinical Wear
Full Wrap-Around Coverage
The vest and skirt combination protects the front and back of both the upper and lower torso.
Two-Piece Construction
Separating the vest and skirt helps distribute garment weight between the shoulders, waist and hips.
Full-Overlap Front
Overlapping front panels provide enhanced shielding through the central frontal region when correctly positioned.
Padded Shoulders
Soft shoulder padding helps reduce concentrated pressure during prolonged procedures.
Secure Closure System
Hook-and-loop closures, support straps, buckle fastening and waist support help maintain a stable fit.
Dosimeter Pocket
A front pocket provides a convenient location for a personal radiation dosimeter badge where required.
PU-Coated Outer Fabric
The outer covering is intended for routine clinical use and cleaning according to current care instructions.
Multiple Core Options
Available with conventional lead-vinyl and lead-free radiation-protection core materials.
Extended-Procedure Comfort
The weight-distributing two-piece format is particularly useful where protection garments are worn for longer procedures.
Choose the Balance of Weight, Shielding and Procurement Requirements
Four core-material options are available. Approximate values below are core area densities per square metre, not finished vest-and-skirt garment weights.
StPb® — Conventional Lead-Vinyl
Approximate core area density: 4.62 kg/m² at 0.35 mmPb and 6.60 kg/m² at 0.50 mmPb.
NoPb®-LT — Lead-Free Lightweight
Approximate core area density: 4.50 kg/m² at 0.35 mmPb and 6.00 kg/m² at 0.50 mmPb.
NoPb®-SL — Lead-Free Super Lightweight
Approximate core area density: 3.90 kg/m² at 0.35 mmPb and 5.20 kg/m² at 0.50 mmPb. It has the lowest listed area density among the four current options.
NoPb®-BL — Lead-Free Broad-Beam Tested
Approximate core area density: 4.29 kg/m² at 0.35 mmPb and 6.00 kg/m² at 0.50 mmPb.
For Procedures Requiring Comprehensive Front and Rear Protection
The garment is intended for professional radiation-protection use in healthcare environments where clinicians may require protection from both frontal and rear scatter during routine or extended procedures.
Cardiac Cath Labs
For fluoroscopy-guided cardiac procedures where staff may remain near the radiation field for extended periods.
EP Laboratories
Suitable for prolonged electrophysiology procedures involving fluoroscopic imaging.
Interventional Radiology
For image-guided interventions requiring comprehensive wearable radiation protection.
C-Arm Procedures
For surgical teams working around mobile fluoroscopy equipment during image-guided procedures.
Radiology Departments
For radiologists, technicians and supporting personnel working around diagnostic X-ray equipment.
Urology Procedures
For clinicians working with fluoroscopic imaging in urology and related procedure rooms.
Technical Specifications
| Product Type | Full Protection Full-Overlap Wrap Around Lead Vest & Skirt |
|---|---|
| Garment Construction | Two-piece protective garment comprising an upper wrap-around vest and lower wrap-around skirt |
| Core-Material Options | StPb®, NoPb®-LT, NoPb®-SL and NoPb®-BL |
| Front Protection | 0.35 mmPb or 0.50 mmPb lead equivalent |
| Full-Overlap Region | Approximately 0.70 mmPb with the 0.35 mmPb model and 1.00 mmPb with the 0.50 mmPb model when correctly overlapped |
| Back Protection | 0.25 mmPb lead equivalent |
| Coverage | Front and rear protection of upper and lower torso, extending toward just above the knee depending on selected size |
| Closure System | Hook-and-loop closure with supporting straps, buckle fastening and waist support |
| Shoulder Support | Padded shoulders for improved wearing comfort |
| Dosimeter Pocket | Front pocket for personal dosimeter badge placement |
| Outer Fabric | Polyurethane-coated outer fabric |
| Available Sizes | XS, S, M, L, XL and XXL |
| Colour Options | Available in multiple colours; customization may be subject to order quantity and production feasibility |
| Recommended Users | Radiologists, cardiologists, surgeons, technicians, nurses and other professionals requiring comprehensive wearable radiation protection |
| Manufacturer | IndoSurgicals Private Limited, New Delhi, India |
What to Confirm Before Ordering
Protection Level
Select 0.35 mmPb or 0.50 mmPb frontal protection according to the approved radiation-safety requirement.
Core Material
Choose conventional lead-vinyl or a lead-free core according to shielding, weight and documentation requirements.
Correct Overlap
Full-overlap performance depends on the front panels being correctly positioned and maintained in the intended overlapping configuration.
Vest & Skirt Fit
Confirm the correct garment size so intended front, rear and overlap coverage are maintained during normal working posture.
Protect the Radiation-Shielding Core from Avoidable Damage
Recommended Handling
Store the vest and skirt flat or on suitable radiation-protection garment hangers. Avoid folding, sharp creasing or placing heavy objects on the protective core. Clean the outer surface using a compatible mild cleaning method and allow the garments to dry before storage.
Routine Inspection
Inspect the fabric, seams, closures, buckles, straps, shoulder support and skirt fastening regularly. Follow the facility schedule for integrity inspection and remove either garment from use if shielding-core damage is suspected.