Medical Equipment Manufacturer
Certified Quality System ISO 9001 & ISO 13485
Quotation list Enquiry Cart 0
IndoSurgicals Product

Ambulance Stretcher with Folding Legs

Manufacturer Direct Bulk & Export Enquiries Product Selection Support
Request pricing

Get a Free Quotation

No obligation
SKU 10306 Brand IS IndoSurgicals®

Add this product to your enquiry cart and submit all required products together for one consolidated quotation.

Need assistance? Mon–Sat · 10:00 AM–5:00 PM IST
Call +91 9350093400
Complete information

Product Details

Emergency Patient Transport · Ambulance Loading Stretcher

Ambulance Stretcher with Folding Legs, Adjustable Backrest & 181 kg Load Capacity

The IndoSurgicals Ambulance Stretcher with Folding Legs is a wheeled emergency patient-transport stretcher designed for loading, unloading and moving patients in compatible ambulances and healthcare environments. Manufactured from high-strength aluminium alloy, it combines mechanically folding legs, an adjustable backrest, cushioned waterproof patient surface, safety locking arrangement and approximately 125 mm castors. The current published load-bearing capacity is 181 kg.

181 kg Published Load Folding Leg Mechanism Adjustable Backrest Approx. 125 mm Castors

Wheeled Ambulance Loading Stretcher for Emergency Patient Transport

Unlike manually carried folding stretchers, this IndoSurgicals Ambulance Stretcher incorporates a wheeled undercarriage and mechanically folding legs to support patient movement between ground level, healthcare environments and compatible ambulance loading decks.

The frame is manufactured from high-strength aluminium alloy. In its high position, the published overall dimensions are 190 × 54 × 90 cm. The stretcher can be lowered to approximately 190 × 54 × 25 cm, allowing the leg assembly to fold beneath the patient platform for ambulance loading and low-level positioning.

A foam-cushioned patient platform with waterproof covering provides a practical support surface, while the adjustable backrest allows the patient's upper-body position to be changed when clinically appropriate.

Buyers searching for an Ambulance Stretcher manufacturer in India, Ambulance Stretcher with folding legs, Ambulance Loading Stretcher, Emergency Stretcher Trolley, Aluminium Ambulance Stretcher, 181 kg patient stretcher or Ambulance Stretcher exporter from India can contact IndoSurgicals for current specifications, compatibility requirements and quotation.

Folding Leg Mechanism

Mechanical legs fold to support loading and unloading from compatible ambulance vehicle platforms.

Aluminium Alloy Frame

High-strength aluminium alloy construction forms the main stretcher and undercarriage structure.

Adjustable Backrest

Backrest can be repositioned according to patient-support and transport requirements.

Cushioned Patient Surface

Foam cushioning with waterproof covering provides a practical patient-support platform.

Safety Lock

A safety locking arrangement is incorporated into the stretcher design for secure positioning.

125 mm Castors

Current specification lists an approximate castor size of 125 mm for wheeled movement.

Mechanically Folding Legs for Ambulance Loading & Unloading

The stretcher uses a mechanically folding undercarriage controlled by handles located on both sides. During appropriate ambulance loading, the leg assembly can fold beneath the patient platform as the stretcher transitions to the lower position.

The current specification also describes a three-step design intended to accommodate the height of the ambulance carriage bottom board. Vehicle compatibility should be confirmed before procurement because ambulance deck heights and retention systems can vary.

High Transport Position

Published high-position dimensions are 190 × 54 × 90 cm, providing a wheeled transport height for movement outside the vehicle.

Low / Loading Position

Published low-position dimensions are 190 × 54 × 25 cm, with the leg assembly folded beneath the patient platform.

One-person operation clarification: the current specification states that the mechanical folding-leg system can be operated by one person using the side handles. This refers to operation of the stretcher mechanism and does not mean that every patient transfer or loading procedure should be performed by one person. Staffing should follow patient condition, patient weight, vehicle design and the healthcare provider's safe-handling protocol.

Foam-Cushioned Waterproof Surface with Adjustable Backrest

The patient-support surface is described as a foamed cushion with waterproof material. This provides a padded transport surface and supports routine cleaning between uses using methods compatible with the supplied materials.

Foam Cushion

Cushioned support surface provides padding during patient transportation.

Waterproof Covering

Current specification identifies the patient surface covering as waterproof material.

Adjustable Back Section

Backrest elevation can be changed when a different upper-body position is required.

181 kg Published Load Capacity with High & Low Positions

190 × 54 × 90 cm

High Position

Published overall dimensions with the stretcher undercarriage raised.

190 × 54 × 25 cm

Low Position

Published dimensions with the stretcher lowered for loading or positioning.

40 kg

Self-Weight

Published finished stretcher weight in the current product specification.

181 kg

Load Bearing Capacity

Current published load-bearing capacity for this Ambulance Stretcher model.

Capacity note: the current product page uses the term Load Bearing Capacity: 181 kg. The figure is preserved exactly and has not been re-labelled as a certified Safe Working Load unless the applicable product documentation specifically defines it that way.

Wheeled Patient Movement with Approximately 125 mm Castors

The stretcher is fitted with castors for movement through compatible ambulance loading areas and healthcare environments. The current specification lists the castor diameter as approximately 125 mm.

Wheeled Transport

Castor-based undercarriage allows the stretcher to be rolled rather than manually carried during suitable portions of patient transfer.

Folding Undercarriage

The wheeled leg assembly folds beneath the platform to transition between normal transport and ambulance-loading positions.

Safety Lock with Patient-Support Features

The published specification includes a safety lock intended to secure the stretcher during transport and loading operations.

Current official product photography also shows raised side support rails and patient securing straps. Because their exact dimensions, number, locking mechanism and restraint specification are not separately defined in the text specification, they are treated here as visible product features rather than independently certified technical claims.

Safety Lock

Current specification confirms a locking feature for securing the stretcher during transport.

Side Support Rails

Current official imagery shows side rails along the patient-support area; confirm supplied configuration.

Patient Securing Straps

Straps are visible in current official imagery; exact restraint specification should be confirmed for the supplied unit.

Applications of Ambulance Stretchers with Folding Legs

This stretcher is intended for emergency and patient-transport environments where a wheeled stretcher must transition between ground-level movement and ambulance loading.

Ambulance Services

Designed for compatible ambulances requiring a mechanically folding loading stretcher.

Emergency Medical Services

Suitable for emergency-response teams transporting patients between vehicles and healthcare facilities.

Hospitals

Can support patient movement from ambulance reception areas into emergency departments.

Emergency Departments

Useful where wheeled patient-transfer equipment interfaces with incoming ambulance transport.

Clinics & Healthcare Facilities

Suitable where ambulance-compatible patient transfer equipment is required.

Institutional Ambulances

Can be specified for industrial, institutional or healthcare ambulance fleets subject to vehicle compatibility.

Ambulance Stretcher with Folding Legs Specifications

Product Type Wheeled Ambulance Stretcher with Mechanical Folding Legs
Frame Material High-strength aluminium alloy
Loading Design Three-step design according to ambulance carriage bottom-board height
Leg Mechanism Mechanically folding legs controlled through operating handles on both sides
High Position 190 × 54 × 90 cm
Low Position 190 × 54 × 25 cm
Self-Weight 40 kg
Published Load Bearing Capacity 181 kg
Patient Surface Foamed cushion with waterproof material
Backrest Adjustable
Safety Feature Safety locking arrangement
Castor Size Approximately 125 mm
Side Rails Visible in current official product imagery; exact specification should be confirmed
Patient Securing Straps Visible in current official product imagery; exact supplied restraint specification should be confirmed
Typical Applications Ambulances, EMS, emergency departments, hospitals and ambulance-compatible patient transport
Compatibility note: ambulance stretcher installations should be matched to the vehicle's loading height, floor arrangement and retention system. Confirm ambulance compatibility and the exact supplied locking / mounting arrangement before procurement.

Ambulance Stretcher vs Two-Fold & Four-Fold Stretchers

All three products sit within the IndoSurgicals Ambulance & Folding Stretchers category, but they serve distinctly different patient-transport requirements.

Ambulance Stretcher

This model has wheels, folding legs, adjustable backrest and vehicle-loading functionality.

Two-Fold Stretcher

Portable manually carried aluminium stretcher with two-fold storage design and carry bag.

Four-Fold Stretcher

Portable manually carried model designed to fold into a particularly compact stored form.

Category distinction: choose the Ambulance Stretcher when wheeled movement and ambulance loading are required. Choose Two-Fold or Four-Fold models when a manually carried portable stretcher is required.

Inspect the Stretcher and Loading Mechanism Before Use

Ambulance loading stretchers contain moving undercarriage, locking and positioning components. These parts should be inspected before patient transport and before loading the stretcher into a vehicle.

Check Folding Legs

Verify that the leg mechanism moves correctly and fully engages in the intended transport position.

Check Locks & Castors

Inspect locking components, wheels and mechanical connections before placing the stretcher into service.

Use Trained Personnel

Patient transfer, loading and unloading should follow appropriate ambulance and healthcare handling procedures.

Patient safety note: the presence of a folding-leg mechanism that can be operated by one person does not remove the need for appropriate staffing. Consider patient condition, patient weight, ambulance height, terrain and transfer method when determining how many trained personnel are required.

Maintain the Frame, Cushion, Castors and Folding Mechanism

Clean Patient Surfaces

Clean and disinfect the waterproof-covered patient surface using methods compatible with the supplied materials.

Inspect Mechanical Parts

Periodically inspect folding legs, handles, locking points, hinges and frame connections.

Check Castors

Inspect castors for damage, abnormal movement, wear or obstruction before patient transport.

Ambulance Stretcher Manufacturer and Supplier in India

IndoSurgicals Private Limited manufactures and supplies hospital furniture, ambulance stretchers, emergency patient-transport products and medical equipment for hospitals, ambulance operators, emergency-service providers, healthcare institutions, dealers, distributors, project buyers and international customers.

Buyers searching for an Ambulance Stretcher manufacturer in India, Ambulance Loading Stretcher supplier, Ambulance Stretcher with folding legs, Aluminium Ambulance Stretcher, Emergency Stretcher Trolley, 181 kg Ambulance Stretcher, Folding Leg Patient Stretcher or Ambulance Stretcher exporter from India can contact IndoSurgicals for current specifications, vehicle compatibility requirements, quantity and quotation.

Request a Quote for Ambulance Stretchers

Share the required quantity, delivery destination and, where applicable, ambulance floor/loading-height information for current specifications, compatibility confirmation and commercial quotation.

Ambulance Stretcher FAQs

What is an Ambulance Stretcher with Folding Legs?
It is a wheeled patient-transport stretcher with a mechanical undercarriage that folds beneath the patient platform during appropriate ambulance loading and unloading.
What material is the stretcher made from?
The current product specification states high-strength aluminium alloy construction.
What is the load-bearing capacity?
The current published load-bearing capacity is 181 kg. Confirm the applicable manufacturer documentation where a formally defined Safe Working Load is required.
What are the dimensions in the high position?
The published high-position dimensions are 190 × 54 × 90 cm.
What are the dimensions in the low position?
The published low-position dimensions are 190 × 54 × 25 cm.
How much does the stretcher weigh?
The current published self-weight is 40 kg.
Does the stretcher have an adjustable backrest?
Yes. The current specification includes an adjustable backrest for changing the patient's upper-body position.
What is the patient surface made from?
The patient-support surface is described as a foamed cushion with waterproof material.
What size are the castors?
The current specification lists the castor size as approximately 125 mm.
Can one person operate the Ambulance Stretcher?
The current specification states that the mechanical folding-leg system can be operated through handles on both sides by one person. This relates to operation of the mechanism only. The number of personnel needed for actual patient movement, lifting, loading or unloading should be determined by patient weight, condition, environment and local safe-handling procedures.
Will this stretcher fit every ambulance?
Compatibility should not be assumed. Ambulance deck height, floor dimensions, loading geometry and retention systems vary. Confirm compatibility with the intended vehicle before ordering.
Does it have side rails and patient straps?
Side rails and patient securing straps are visible in current official product photographs. Their exact dimensions, number and restraint specification are not separately stated in the published technical details, so confirm the supplied configuration when these are procurement requirements.
What is the difference between this and the Two-Fold or Four-Fold Stretcher?
This Ambulance Stretcher is wheeled and uses mechanically folding legs for vehicle loading. The Two-Fold and Four-Fold products are compact manually carried portable stretchers supplied with carry bags.
How should the stretcher be maintained?
Inspect the aluminium frame, folding-leg mechanism, operating handles, locks, castors, backrest and patient-support surface regularly. Clean and disinfect surfaces using methods compatible with the supplied materials.
Patient-transport note: use the stretcher only with a compatible ambulance loading arrangement and according to trained patient-handling procedures. Confirm the current rated capacity, inspect the stretcher and mechanical locks before use, secure the patient appropriately and use sufficient trained personnel for the patient's condition, weight and transfer environment.